REVERSE OSMOSIS DRINKING WATER SYSTEMS INSTALLATION, OPERATION & SERVICE MANUAL 220 Bayview Drive, Unit 18 Barrie, O
C. Drain Clamp Installation Choose the drain outlet location. The following are instructions for discharging in the sink drain pipe. (Refer to Fig.
D. Position the Drinking Water Holding Tank and Make the Final Hose Connections 1. Check the tank pre-charge pressure. Make sure it is between 5 to
OPERATION & MAINTENANCE A. Normal Operation 1. Reverse Osmosis systems produce drinking water at relatively slow rates, it can take up to 3 ho
3 ml) into the tubing and reconnect it to the Tee. NOTE: Now is the convenient time to change the In-Line Activated Carbon Post Filter. • Slowly open
TROUBLE SHOOTING GUIDE Problem Possible Cause Solution Feed Water Ball Valve is plugged or closed. Open Valve or unclog. Clogged Sediment Pre-filter
Problem Possible Cause Solution The Product Water and Drain Water lines are reversed. Correct plumbing. No drain flow, Drain Restrictor is clogged.
14
TABLE OF CONTENTS Page INTRODUCTION 1 . PREPARATION A. Major System Components 2 Installation Drawing 3 B. Tools Recommended f
INTRODUCTION Your new Reverse Osmosis Drinking Water System uses a combination of filtration technologies to reduce unwanted contaminants in your
PREPARATION A. Major System Components 9. A Sediment Pre-filter, shrink wrapped. The following components comprise the Reverse Osmosis Drinking W
3 BALL C. Site Selection for Major System Components 3
B. Tools Recommended for Installation The following tools will cover most of the installation sites encountered: 1. 3/8" variable speed electr
4. Feed Water Connection – The Feed Water Ball Valve should be located as close to the manifold assembly as possible. USE A POTABLE COLD WATER SUPP
LONG REACH FAUCET Figure 2A 6
B. Feed Water Ball Valve Installation Decide on location. Do NOT connect to a hot water feed line. If you are not sure of the supply, run the hot wat